SAP vs SBEM

It sounds like one of those questions that should have a very simple answer. Do I need SAP or SBEM?

For the most part, it does.

If you are building a house or flat, you are generally looking at SAP. If you are developing an office, warehouse, shop or other commercial building, it will usually be SBEM.

Unfortunately, buildings have a habit of making seemingly simple questions rather less straightforward.

Throw in a mixed-use development, a commercial-to-residential conversion, a garden room or a building with several different uses and suddenly the answer isn’t quite so obvious.

We regularly speak to developers and project teams who have reached a fairly advanced stage before somebody asks which energy assessment they actually need. The calculation itself isn’t necessarily the problem. Finding out too late that the wrong route has been assumed can be.

So, what is the difference?

SAP stands for Standard Assessment Procedure and is used to assess the energy performance of dwellings. It is typically required for new-build houses and flats, as well as residential conversions where a new dwelling is being created.

SBEM, or Simplified Building Energy Model, is the methodology generally used for non-domestic buildings such as offices, shops, warehouses, schools, healthcare buildings and other commercial premises.

Both are used to demonstrate energy performance, but they assess different types of buildings and shouldn’t be treated as interchangeable.

The important point is that they are more than just calculations carried out at the end of a project to satisfy Building Control. The result is affected by decisions being made throughout the design process.

For SAP, that includes the building fabric, insulation, glazing, heating, hot water, ventilation, air permeability, thermal bridging and renewables.

SBEM looks at many of the same principles but applies them to non-domestic buildings, taking account of the building’s use, layout and services, including heating, cooling, ventilation, lighting, hot water, controls and zoning.

And that is where things can start getting interesting.

When a building doesn’t fit neatly into a box

A mixed-use development is a good example.

Take flats above a retail unit. The flats are dwellings so SAP would normally apply. The shop underneath is commercial, so that part would normally require SBEM.

So far, so simple.

But what happens to the shared entrance, communal areas, plant rooms and services serving different parts of the building?

Those are the details that need to be understood properly rather than simply assuming the whole development can be dealt with in the same way.

Conversions can raise similar questions. If a commercial property is being converted into residential accommodation, the assessment route changes with the use of the building. Again, it is much easier to establish that at the design stage than after specifications have been agreed and work has started.

We also receive enquiries about smaller detached buildings such as heated garden rooms, studios and gyms. They may feel very much like part of somebody’s home but depending on their size, use and the interpretation of Building Control, the compliance route may not be as obvious as the owner expects.

The answer isn’t to overcomplicate every project. It is simply to ask the question early enough.

SBEM isn’t always the answer for every commercial building

Even within non-domestic buildings there are different levels of complexity.

A relatively straightforward warehouse is very different from a large healthcare building, school or multi-let office with numerous zones, heating and cooling systems and different occupancy patterns.

In more complex cases, SBEM may not be sophisticated enough and Dynamic Simulation Modelling, or DSM, may be required instead.

This is one of the reasons we are wary of treating energy assessments as a commodity. Choosing an assessor or methodology purely because it appears to be the quickest or cheapest option doesn’t help if it isn’t appropriate for the building.

The model needs to reflect what is actually being designed.

SAP and SBEM aren’t EPCs either

This is another area where terminology frequently gets muddled.

SAP and SBEM are calculation methodologies. An Energy Performance Certificate records an energy performance rating.

They are related but they aren’t the same thing.

A new house may require a SAP calculation to demonstrate compliance with Building Regulations and subsequently receive a domestic EPC. A new commercial building may require an SBEM assessment and BRUKL report for Building Regulations compliance, followed by a commercial EPC.

An existing commercial building, meanwhile, might need an EPC because it is being sold or let without requiring the sort of design-stage SBEM assessment associated with a new development.

It sounds like a small distinction but understanding what the assessment is actually being carried out for makes a considerable difference.

Don’t leave the energy assessment until the end

This is probably our biggest frustration with both SAP and SBEM work.

Too often the energy calculation arrives towards the bottom of the project team’s to-do list, when drawings are substantially complete, products have been specified and costs agreed.

If the building then fails there is far less room to manoeuvre.

Suddenly the conversation is about increasing insulation, changing glazing, reviewing heating or ventilation systems, improving air tightness or adding renewable technology. None of which is particularly welcome when a contractor is waiting for a decision or the client believes the design is finished.

Bring the assessment into the design process earlier and there are usually more options.

That doesn’t mean designing a building around a piece of software. Quite the opposite. The calculation should help the design team understand whether the decisions they are already making are taking the building in the right direction.

It also means giving the assessor decent information.

Plans, elevations, sections, construction details, U-values, glazing specifications and information about heating, ventilation, lighting and renewables all help reduce the number of assumptions that have to be made.

And, as we’ve said before when talking about EPC assessments, assumptions aren’t always kind to the result.

What about MEES?

For an existing commercial property the conversation may be slightly different again.

A landlord may not be particularly interested in SAP or a new-build SBEM calculation. Their concern may be the building’s EPC and whether its rating presents a Minimum Energy Efficiency Standards (MEES) risk.

The subjects are connected because they all sit within the wider world of building energy performance, but the purpose of the assessment is different.

It is therefore worth being clear from the outset whether the question is about Building Regulations, producing an EPC, assessing an existing building or understanding future compliance risk.

Those are very different conversations.

The simple rule

If it is a dwelling, start by thinking SAP.

If it is non-domestic, start with SBEM.

If it contains both, has an unusual use or is being converted from one use to another, don’t assume.

Get somebody to look at it.

A five-minute conversation at the beginning of a project is considerably easier than redesigning parts of a building at the end because everybody assumed the wrong assessment would apply.

At Murton & Co we work with developers, architects and project teams on SAP and SBEM calculations, Building Regulations compliance and EPCs. Our role isn’t simply to produce a calculation at the end of the process. Where possible, we would much rather identify the right route early and help the project team understand what information and decisions will affect the outcome.

Because when it comes to energy compliance, finding out sooner is nearly always cheaper than finding out later.

Here are some common questions we get asked:

Can a project need both SAP and SBEM?

Yes. Mixed-use developments can require SAP for the residential parts and SBEM for the non-domestic areas. The exact split depends on how the building is arranged and used.

Is SBEM the same as a commercial EPC?

No. SBEM is a calculation methodology used to assess the energy performance of non-domestic buildings. A commercial EPC is the certificate that records the building’s energy rating.

When should SAP or SBEM be carried out?

As early as possible in the design process. Early assessment gives the project team more scope to address issues with fabric, glazing, services, ventilation or renewables before the design is fixed.

What happens if a SAP or SBEM calculation doesn’t comply?

The design or specification may need to be reviewed. Depending on the project, that could mean changes to insulation, glazing, heating, ventilation, lighting, air tightness or renewable technologies.

Murton & Co can help

Murton & Co supports developers, architects, consultants and project teams with SAP calculations, SBEM calculations, EPCs and wider building performance advice.

We help clients understand what is needed, when it is needed and what information is required to keep the project moving.

Whether you are planning a new development, dealing with a mixed-use scheme, converting an existing building or responding to a Building Control query, early advice can reduce risk and avoid last-minute surprises.

For SAP, SBEM and compliance advice, contact Murton & Co.

Need SAP or SBEM advice?

If you are unsure whether your project needs SAP calculations, SBEM calculations or both, speak to Murton & Co before the design is too far developed.

Getting us involved early can help identify the right route, the right information and any obvious compliance risks before they become expensive to fix.

Contact Murton & Co to discuss your project.

Get a quote

Getting us involved on your next project is just an email away.

Service(s) required* :